ICHEM+ FEATURES
- Analysis method : Kinetic, End point, Two-point (fixed time), Absorbance
- 7-inch color LCD with touch screen ARM series high speed micro CPU
- 10 built-in incubators at 37°C, 30°C or 25°C, ± 0.1°C & 3 timers with alarm
- 6V/10W Halogen Lamp with long life span Light path 10 mm
- 7 wavelengths, 340, 405, 492, 510, 546, 578 and 630 nm, 1 extra optional,
- Flow-cell and cuvette mode
- Reagent volume 0 to 3000 !L (>500 !L recommended)
- Measuring volume : 32 uL
- 90 programmable assays
- Real-time display of reaction curve
- Light source auto sleep function
- Data Storage 10,000 sample results
- Built-in printer, RS-232 interface
- Absorbance range 0 to 4.5 Abs, Precision 0.0001 Abs
AUTOCHEM XPERT FEATURES
- Fully Automated, STAT priority random access chemistry analyzer.
- Constant throughput of 150T/H with double reagents.
- Integrated and fully closed optical system with 8 wavelengths and absorbance range up to 4 Abs.
- User friendly software interface simple, easy-to-operation.
- 40 Reagent and 40 sample positions with in-built barcode reader.
- Non-stop cooling with Peltier pad inside.
- Minimum reaction volume as low as 150 μl, saves cost.
- 44 individual new amorphous plastic reaction cuvettes for perfect transmittance.
- Multi stage (2x4) on-board laundry for automatic cleaning and drying of cuvettes.
- External and Internal mirror polish probe equipped with sensitive liquid sensor,tracking of liquid volume & collision avoidance
- Teflon coated & paddle type gives excellent mixing effect with no water dripping which eliminates carryover.
- High precision permanent ceramic syringe with accurate dispensing of volume as low as 0.1 μl
- Water consumption of maximum 6L/hour.
- Reaction result automatic checking and warning, calibration result automatic checking, warning alarm log
- Linear & nonlinear calibration, Multi-points calibration up to 8 points
- Quality control feature using Westgard, L-J plot and cumulative principles
- TCP/IP Network Interface
AUTOChem Reagents List
Cat. No. | Product, Method | Method | Pack Size | Content |
---|---|---|---|---|
AB7140 | Albumin | BCG | 4x35 ml | Single Reagent |
AP7160 | Alkaline Phosphatase | mod.IFCC | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
AY7030 | Alpha Amylase | CNP-G3 | 2x15 ml | Single Reagent |
BD7160 | Bilirubin Auto Direct | DCA | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
BT7160 | Bilirubin Auto Total | DCA | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
CA7140 | Calcium | Arsenazo | 4x35 ml | Single Reagent |
BC7140 | Carbon Dioxide (CO2) | PEP-C | 4x35 ml | Single Reagent |
HD7080 | Cholesterol HDL | Direct | 2x40 ml | 2x30 mlR1, 2x10 mlR2 |
LD7040 | Cholesterol LDL | Direct | 1x40 ml | 1x30 mlR1, 1x10 mlR3 |
CH7140 | Cholesterol | CHOD-PAP | 4x35 ml | Single Reagent |
CK7030 | CK-MB | DGKC | 2x15 ml | 2x12 mlR1, 2x3 mlR2 |
CN7030 | CK-NAC | DGKC | 2x15 ml | 2x12 mlR1, 2x3 mlR2 |
CE7160 | Creatinine | Enzymatic | 4x40 ml | 4x30 mlR1, 4x10 mlR2 |
CR7160 | Cholesterol HDL | mod. Jaffe | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
GT7080 | Gamma GT | IFCC | 2x40 ml | 2x30 mlR1, 2x10 mlR2 |
GL7140 | Glucose | GOD-PAP | 4x35 ml | Single Reagent |
AS7160 | GOT(AST) | mod.IFCC | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
CR7160 | Cholesterol HDL | mod. Jaffe | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
CR7160 | Cholesterol HDL | mod. Jaffe | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
AL7160 | GPT(ALT) | mod.IFCC | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
HB7040 | HbA1c Direct | Latex immunoturbid | 1x40 ml | 1x30 mlR1, 1x10 mlR2 |
IR7030 | Iron | Ferene | 2x15 ml | 2x12 mlR1, 2x3 mlR1 |
LH7030 | LDH | L-P | 2x15 ml | 2x12 mlR1, 2x3 mlR2 |
LI7030 | Lipase | Enzymatic Colorimetric | 2x15 ml | 2x12 mlR1, 2x3 mlR3 |
PH7140 | Phosphorus Inorganic | Molybd. | 4x35 ml | Single Reagent |
UP7070 | Protein Total in Urine with 1ml Std. | Pyrogallol Red | 2x35 ml | Single Reagent |
TP7140 | Protein Total | Biuret | 4x35 ml | Single Reagent |
TG7140 | Triglycerides | GPO-PAP | 4x35 ml | Single Reagent |
UI7030 | UIBC | Ferene | 2x15 ml | 2x12 mlR1, 2x3 mlR1 |
UR7160 | Urea UV Auto | Urease/GLDH | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
UA7160 | Uric Acid TBHBA | Enzym.Color. | 4x40 ml | 4x32 mlR1, 4x8 mlR2 |
ASO7040 | ASO with 1ml Cal. | Immunoturbidimetric | 1x40 ml | 1x30 mlR1, 1x10 mlR2 |
CRP7040 | CRP with 1ml Cal. | Immunoturbidimetric | 1x40 ml | 1x30 mlR1, 1x10 mlR2 |
RF7040 | RF with 1ml Cal. | Immunoturbidimetric | 1x40 ml | 1x30 mlR1, 1x10 mlR2 |
MAL7040 | Microalbumin with 1ml Cal. | Immunoturbidimetric | 1x40 ml | 1x30 mlR1, 1x10 mlR2 |
DIRUI CS-T240 PLUS FEATURES
- Fully Automated, discrete, STAT priority random access analyzer
- Constant throughput of 240 photometry tests per hour
(480 tests her hour with ISE) - Flat field grating type beam-splitting system
- Simultaneous photometric data collection and processing of 12 wavelengths
- Minimum reaction volume of 100 µ
- Sample/reagent disc – 40 standard positions can be increased up to 8
- 56, optical plastic reaction cuvettes
- On-board laundry – 8 stops 12 steps by warm water rinsin
- Water consumption of only 3L per hour
- Water quality check function, ensure the water meets the requirements, keep accurate results
- Reagent inventory management, automatically calculates remaining volume and remaining number
- HIS/LIS interface connectivity, remote maintenance support
- Whole blood testing function for HbA1c to avoid artificial error
- Automatic hemolysis function, easy operation and standardization for HbA1c test
DIRUI CS480 FEATURES
- Fully automated discrete random access analyser
- Constant throughput of 400 photometry tests per hour (800 tests her hour with ISE)
- Holographic concave flat field grating with rear spectrophotometry and cluster optical path to achieve micro volume detection of reaction solution
- Minimum reaction volume 120uL
- 3 stand-alone probes - one probe for sample and two probes for reagent.
- 112 oblique design reagent positions for full use reagent to save reagent and cost.
- Up to 115 elastic design sample positions, suitable for different size of tubes
- Digital liquid detection high sensitivity avoids bubbles interference
- Polished probe with functions of automatic liquid level detection, collision protection, clot detection and automatic resetting.
- Automatically cuvette check-up to ensure that cuvettes are clean.
- Two independent flat paddle mixers blending immediately after joining reagent.
- On-board laundry – 7 stops 11 steps by warm water rinsing
- Rear spectrophotometry of holographic concave flat field grating
- Maintenance free high precision long life ceramic piston syringe, ensures high precision in sampling.
- Up to 4 reagents testing (R1, R2, R3, R4)
- Bi-directional LIS/HIS system to realize remote operation, and minimal maintenance.
- NGSP certification of whole blood latex-agglutinationmethod on analyzer.
- Whole blood testing function for HbA1c to avoid artificial error
- Automatically hemolysis function, easy operation and standardization for HbA1c test
DIRUI CS-1300B
- Fully automated discrete random access analyser
- Throughput of 900 singe/dual reagent test/hr. without ISE or 1350 tests/hour with ISE.
- Holographic concave flat field grating with rear spectrophotometry and cluster optical path to achieve micro volume detection of reaction solution
- 3 stand-alone probes - one probe for sample and two probes for reagent.
- Semiconductor refrigerated double reagent discs with 132 positions.
- Cooled positions for calibrators and controls. 140 positions sample tray with calibrator and control.
- 60 nm polished probe with automatic digital liquid level detection, collision protection and clot detection.
Diatron P700
- The Pictus 700 is a fully automated, random access, small footprint floor clinical chemistry analyzer
- The system can achieve a photometric throughput of up to 600 tests/hour & max 720 tests/hour with optional ISE unit. Optimized walkaway operation.
- 95 (5 racks x 19 positions) ID barcode equipped positions for routine, stat and control samples and standard solution..
- The 72 reagent positions (75 w/ISE) and onboard refrigeration allow for many tests to be kept on the analyzer at the same time.
- 160 reusable PMMA reaction cuvette.
- More savings will be realized by utilizing low cost reagent, calibrator and controls reducing the overall cost per reportable result
- Clot, crash and liquid detection features on both probes, pre-heated probes for faster test times
- Water consumption of less than 5L per hour
- Automatic pre-dilution and post dilution (ratio 1:5 to 1:100)
- Full quality control: Levey-Jennings plots, Westgard multi-rules
- Optimized washing system & automatic cuvette check prior to use.
- Windows based operating system with graphically represented menus and easy-to-use icons
- US-FDA 510(K) cleared
Indiko
- Photometric tests/hour: up to 200
- Max 90 with 5 x 18-pos. sample rack and 1 x 6-pos. reagent rack
- Max 30 with 1 x 9 -or 18-pos. sample rack
- Up to 2 hours
- 1.5 liter / hour
- 75 cm x 70 cm x 62 cm / 130 cm with the open cover & 85 kg 29,5 in x 27,6 in x 24,4 in/ 51 in with the open cover & 187 lbs
Indiko Plus
- Photometric tests/hour: up to 350
- Max 108 with 6 x 18-pos. sample rack
- Max 42 reagent positions Up to 3 hours
- 2.5 liters / hour 94 cm x 70 cm x 62 cm / 130 cm with the open cover & 110 kg 37 in x 27,6 in x 24,4 in/ 51 in with the open cover & 242 lbs