GW_InnerBannerImages_IVD (1)

ICHEM+ FEATURES

01

  • Analysis method : Kinetic, End point, Two-point (fixed time), Absorbance
  • 7-inch color LCD with touch screen ARM series high speed micro CPU
  • 10 built-in incubators at 37°C, 30°C or 25°C, ± 0.1°C & 3 timers with alarm
  • 6V/10W Halogen Lamp with long life span Light path 10 mm
  • 7 wavelengths, 340, 405, 492, 510, 546, 578 and 630 nm, 1 extra optional,
  • Flow-cell and cuvette mode
  • Reagent volume 0 to 3000 !L (>500 !L recommended)
  • Measuring volume : 32 uL
  • 90 programmable assays
  • Real-time display of reaction curve
  • Light source auto sleep function
  • Data Storage 10,000 sample results
  • Built-in printer, RS-232 interface
  • Absorbance range 0 to 4.5 Abs, Precision 0.0001 Abs

AUTOCHEM XPERT FEATURES

01

  • Fully Automated, STAT priority random access chemistry analyzer.
  • Constant throughput of 150T/H with double reagents.
  • Integrated and fully closed optical system with 8 wavelengths and absorbance range up to 4 Abs.
  • User friendly software interface simple, easy-to-operation.
  • 40 Reagent and 40 sample positions with in-built barcode reader.
  • Non-stop cooling with Peltier pad inside.
  • Minimum reaction volume as low as 150 μl, saves cost.
  • 44 individual new amorphous plastic reaction cuvettes for perfect transmittance.
  • Multi stage (2x4) on-board laundry for automatic cleaning and drying of cuvettes.
  • External and Internal mirror polish probe equipped with sensitive liquid sensor,tracking of liquid volume & collision avoidance
  • Teflon coated & paddle type gives excellent mixing effect with no water dripping which eliminates carryover.
  • High precision permanent ceramic syringe with accurate dispensing of volume as low as 0.1 μl
  • Water consumption of maximum 6L/hour.
  • Reaction result automatic checking and warning, calibration result automatic checking, warning alarm log
  • Linear & nonlinear calibration, Multi-points calibration up to 8 points
  • Quality control feature using Westgard, L-J plot and cumulative principles
  • TCP/IP Network Interface

AUTOChem Reagents List

Cat. No. Product, Method Method Pack Size Content
AB7140 Albumin BCG 4x35 ml Single Reagent
AP7160 Alkaline Phosphatase mod.IFCC 4x40 ml 4x32 mlR1, 4x8 mlR2
AY7030 Alpha Amylase CNP-G3 2x15 ml Single Reagent
BD7160 Bilirubin Auto Direct DCA 4x40 ml 4x32 mlR1, 4x8 mlR2
BT7160 Bilirubin Auto Total DCA 4x40 ml 4x32 mlR1, 4x8 mlR2
CA7140 Calcium Arsenazo 4x35 ml Single Reagent
BC7140 Carbon Dioxide (CO2) PEP-C 4x35 ml Single Reagent
HD7080 Cholesterol HDL Direct 2x40 ml 2x30 mlR1, 2x10 mlR2
LD7040 Cholesterol LDL Direct 1x40 ml 1x30 mlR1, 1x10 mlR3
CH7140 Cholesterol CHOD-PAP 4x35 ml Single Reagent
CK7030 CK-MB DGKC 2x15 ml 2x12 mlR1, 2x3 mlR2
CN7030 CK-NAC DGKC 2x15 ml 2x12 mlR1, 2x3 mlR2
CE7160 Creatinine Enzymatic 4x40 ml 4x30 mlR1, 4x10 mlR2
CR7160 Cholesterol HDL mod. Jaffe 4x40 ml 4x32 mlR1, 4x8 mlR2
GT7080 Gamma GT IFCC 2x40 ml 2x30 mlR1, 2x10 mlR2
GL7140 Glucose GOD-PAP 4x35 ml Single Reagent
AS7160 GOT(AST) mod.IFCC 4x40 ml 4x32 mlR1, 4x8 mlR2
CR7160 Cholesterol HDL mod. Jaffe 4x40 ml 4x32 mlR1, 4x8 mlR2
CR7160 Cholesterol HDL mod. Jaffe 4x40 ml 4x32 mlR1, 4x8 mlR2
AL7160 GPT(ALT) mod.IFCC 4x40 ml 4x32 mlR1, 4x8 mlR2
HB7040 HbA1c Direct Latex immunoturbid 1x40 ml 1x30 mlR1, 1x10 mlR2
IR7030 Iron Ferene 2x15 ml 2x12 mlR1, 2x3 mlR1
LH7030 LDH L-P 2x15 ml 2x12 mlR1, 2x3 mlR2
LI7030 Lipase Enzymatic Colorimetric 2x15 ml 2x12 mlR1, 2x3 mlR3
PH7140 Phosphorus Inorganic Molybd. 4x35 ml Single Reagent
UP7070 Protein Total in Urine with 1ml Std. Pyrogallol Red 2x35 ml Single Reagent
TP7140 Protein Total Biuret 4x35 ml Single Reagent
TG7140 Triglycerides GPO-PAP 4x35 ml Single Reagent
UI7030 UIBC Ferene 2x15 ml 2x12 mlR1, 2x3 mlR1
UR7160 Urea UV Auto Urease/GLDH 4x40 ml 4x32 mlR1, 4x8 mlR2
UA7160 Uric Acid TBHBA Enzym.Color. 4x40 ml 4x32 mlR1, 4x8 mlR2
ASO7040 ASO with 1ml Cal. Immunoturbidimetric 1x40 ml 1x30 mlR1, 1x10 mlR2
CRP7040 CRP with 1ml Cal. Immunoturbidimetric 1x40 ml 1x30 mlR1, 1x10 mlR2
RF7040 RF with 1ml Cal. Immunoturbidimetric 1x40 ml 1x30 mlR1, 1x10 mlR2
MAL7040 Microalbumin with 1ml Cal. Immunoturbidimetric 1x40 ml 1x30 mlR1, 1x10 mlR2

DIRUI CS-T240 PLUS FEATURES

01

  • Fully Automated, discrete, STAT priority random access analyzer
  • Constant throughput of 240 photometry tests per hour
    (480 tests her hour with ISE)
  • Flat field grating type beam-splitting system
  • Simultaneous photometric data collection and processing of 12 wavelengths
  • Minimum reaction volume of 100 µ
  • Sample/reagent disc – 40 standard positions can be increased up to 8
  • 56, optical plastic reaction cuvettes
  • On-board laundry – 8 stops 12 steps by warm water rinsin
  • Water consumption of only 3L per hour
  • Water quality check function, ensure the water meets the requirements, keep accurate results
  • Reagent inventory management, automatically calculates remaining volume and remaining number
  • HIS/LIS interface connectivity, remote maintenance support
  • Whole blood testing function for HbA1c to avoid artificial error
  • Automatic hemolysis function, easy operation and standardization for HbA1c test

DIRUI CS480 FEATURES

01

  • Fully automated discrete random access analyser
  • Constant throughput of 400 photometry tests per hour (800 tests her hour with ISE)
  • Holographic concave flat field grating with rear spectrophotometry and cluster optical path to achieve micro volume detection of reaction solution
  • Minimum reaction volume 120uL
  • 3 stand-alone probes - one probe for sample and two probes for reagent.
  • 112 oblique design reagent positions for full use reagent to save reagent and cost.
  • Up to 115 elastic design sample positions, suitable for different size of tubes
  • Digital liquid detection high sensitivity avoids bubbles interference
  • Polished probe with functions of automatic liquid level detection, collision protection, clot detection and automatic resetting.
  • Automatically cuvette check-up to ensure that cuvettes are clean.
  • Two independent flat paddle mixers blending immediately after joining reagent.
  • On-board laundry – 7 stops 11 steps by warm water rinsing
  • Rear spectrophotometry of holographic concave flat field grating
  • Maintenance free high precision long life ceramic piston syringe, ensures high precision in sampling.
  • Up to 4 reagents testing (R1, R2, R3, R4)
  • Bi-directional LIS/HIS system to realize remote operation, and minimal maintenance.
  • NGSP certification of whole blood latex-agglutinationmethod on analyzer.
  • Whole blood testing function for HbA1c to avoid artificial error
  • Automatically hemolysis function, easy operation and standardization for HbA1c test

DIRUI CS-1300B

01

  • Fully automated discrete random access analyser
  • Throughput of 900 singe/dual reagent test/hr. without ISE or 1350 tests/hour with ISE.
  • Holographic concave flat field grating with rear spectrophotometry and cluster optical path to achieve micro volume detection of reaction solution
  • 3 stand-alone probes - one probe for sample and two probes for reagent.
  • Semiconductor refrigerated double reagent discs with 132 positions.
  • Cooled positions for calibrators and controls. 140 positions sample tray with calibrator and control.
  • 60 nm polished probe with automatic digital liquid level detection, collision protection and clot detection.

Diatron P700

01

  • The Pictus 700 is a fully automated, random access, small footprint floor clinical chemistry analyzer
  • The system can achieve a photometric throughput of up to 600 tests/hour & max 720 tests/hour with optional ISE unit. Optimized walkaway operation.
  • 95 (5 racks x 19 positions) ID barcode equipped positions for routine, stat and control samples and standard solution..
  • The 72 reagent positions (75 w/ISE) and onboard refrigeration allow for many tests to be kept on the analyzer at the same time.
  • 160 reusable PMMA reaction cuvette.
  • More savings will be realized by utilizing low cost reagent, calibrator and controls reducing the overall cost per reportable result
  • Clot, crash and liquid detection features on both probes, pre-heated probes for faster test times
  • Water consumption of less than 5L per hour
  • Automatic pre-dilution and post dilution (ratio 1:5 to 1:100)
  • Full quality control: Levey-Jennings plots, Westgard multi-rules
  • Optimized washing system & automatic cuvette check prior to use.
  • Windows based operating system with graphically represented menus and easy-to-use icons
  • US-FDA 510(K) cleared

Indiko

01

  • Photometric tests/hour: up to 200
  • Max 90 with 5 x 18-pos. sample rack and 1 x 6-pos. reagent rack
  • Max 30 with 1 x 9 -or 18-pos. sample rack
  • Up to 2 hours
  • 1.5 liter / hour
  • 75 cm x 70 cm x 62 cm / 130 cm with the open cover & 85 kg 29,5 in x 27,6 in x 24,4 in/ 51 in with the open cover & 187 lbs

Indiko Plus

01

  • Photometric tests/hour: up to 350
  • Max 108 with 6 x 18-pos. sample rack
  • Max 42 reagent positions Up to 3 hours
  • 2.5 liters / hour 94 cm x 70 cm x 62 cm / 130 cm with the open cover & 110 kg 37 in x 27,6 in x 24,4 in/ 51 in with the open cover & 242 lbs
YEARS IN BUSINESS
0
+
OUR
EMPLOYEES
0
+
LOCATIONS PRESENCE
0
+
DISTRICTS COVERED
0
+

Request a free consultancy

It is a long established fact that a reader will be distracted by the readable content