P3 and P6
Temperature control system

Hypothermia for HIE
Neonatal hypoxic-ischemic encephalopathy (HIE) is a brain injury disease with a high mortality rate. Therapeutic Hypothermia is regarded as a core treatment for HIE as it helps by maintaining a lower core temperature in newborns for up to 72 hours, effectively lowering mortality by slowing down apoptotic processes and reducing oxygen dependence in the brain.
Traditional hypothermia treatment relies heavily on the use of manual cooling and rewarming methods such as ice packs, in which temperature control is not only inaccurate, but also leaves much room for human error. The current trend in the treatment of HIE has shifted heavily towards Precise Temperature Control by means of cooling devices that provide caregivers with Streamlined Procedures throughout the entire treatment process, hence, the P6.
.png)
Hypothermia for HIE
Neonatal hypoxic-ischemic encephalopathy (HIE) is a brain injury disease with a high mortality rate. Therapeutic Hypothermia is regarded as a core treatment for HIE as it helps by maintaining a lower core temperature in newborns for up to 72 hours, effectively lowering mortality by slowing down apoptotic processes and reducing oxygen dependence in the brain.
Traditional hypothermia treatment relies heavily on the use of manual cooling and rewarming methods such as ice packs, in which temperature control is not only inaccurate, but also leaves much room for human error. The current trend in the treatment of HIE has shifted heavily towards Precise Temperature Control by means of cooling devices that provide caregivers with Streamlined Procedures throughout the entire treatment process, hence, the P6.
.png)

Combining Intelligent Temperature Control and Comprehensive Monitoring for Smart HIE Treatment Management.
Although Therapeutic Hypothermia may be a core treatment for HIE, maintaining a low temperature for long periods of time can manifest in a lot of complications due to the effects of hypothermia on organs, such as acquired infections, seizures or arrhythmias, etc. Timely detection of these complications can be a matter of life-or-death, hence, the perfect monitoring solution is necessary.
Although Therapeutic Hypothermia may be a core treatment for HIE, maintaining a low temperature for long periods of time can manifest in a lot of complications due to the effects of hypothermia on organs, such as acquired infections, seizures or arrhythmias, etc. Timely detection of these complications can be a matter of life-or-death, hence, the perfect monitoring solution is necessary.
State of the Art Comprehensive Temperature Control Solution

More than just Cooling


①: Seetha Shankaran . Therapeutic Hypothermia for Neonatal Encephalopathy 2013 Dec 1. Curr Treat Options Neurol. 2012 Dec; 14(6): 608–619.
Effortless Access
i-Servo™ Temperature Control System
P3/P6's intelligent closed-loop temperature control system automatically adjusts water temperature based on the monitored patient’s core temp. The monitoring of the patient (both skin & core), water temperature ensures the safety throughout treatment, rewarming and maintenance while also avoiding other complications caused by long-term hypothermia.
Quick access buttons on the side of the screen allows caregivers to easily switch between Hypothermia mode and Normothermia mode, tailored for versatility without the hassle when attending to patients' needs.
- Hypothermia Mode comes with an Intelligent Automatic Transition from Cooling-Maintenance treatment to Rewarming when Auto Mode is selected.
- Normothermia Mode is applicable during surgery to help patients maintain stable temperatures, tailored to best meet every unique surgical situation.

Hypothermia mode

Normothermia mode
Seeing is Believing
Our large 12.1” capacitive touchscreen accommodates up to 3 clearly observable temperature trend graphs, granting caregivers better tools when assessing patient conditions. Trend data can be recorded for 80 hours, and high-resolution data can be reviewed in 1 hour intervals for more in-depth analysis. Trend reviews aid medical staff in disease diagnosis, increasing diagnostic accuracy and work efficiency.

Seeing is Believing
Our large 12.1” capacitive touchscreen accommodates up to 3 clearly observable temperature trend graphs, granting caregivers better tools when assessing patient conditions. Trend data can be recorded for 80 hours, and high-resolution data can be reviewed in 1 hour intervals for more in-depth analysis. Trend reviews aid medical staff in disease diagnosis, increasing diagnostic accuracy and work efficiency.







Constant Vigilance
Round-the-clock Protection through Modular Monitoring
Unexpected complications in newborns receiving therapeutic hypothermia can be overwhelming and stressful due to the influence it has on their cardiopulmonary system, which is why, to lighten caregivers’ load, we provide constant monitoring of vital signs to ensure that nothing goes unnoticed.

Round-the-clock Protection through Modular Monitoring
Unexpected complications in newborns receiving therapeutic hypothermia can be overwhelming and stressful due to the influence it has on their cardiopulmonary system, which is why, to lighten caregivers’ load, we provide constant monitoring of vital signs to ensure that nothing goes unnoticed.

NIBP
Convenience
Flexible auto/manual measurement.
Informative
Up to 2000 recordable logs for diagnostic analysis.
SpO2
Reliability
VMasimo SpO2. Reliable and accurate measurement for newborns even with very low perfusion and motion.
Accuracy
Nellcor’s SatSeconds Smart Alarm detects SpO2 changes in an accurate and timely manner.
ECG
Stability
Smart lead detection automatically detects a loose lead and switches channels.
Visual Clarity
Gain and Filter options for clear and easily observable ECG waveforms.
Acuity
Constant monitoring coupled with our ECG and HR alarms provide caregivers with peace of mind during patient care.
RESP
Security
Apnea Alarm
Allowing for more timely response from caregivers.
Intimate Care
Our tried-and-tested water blanket plays a crucial role in temperature transmission during the 72-hour hypothermia treatment. With two types to choose from, they are a perfect complement to the P3/P6, providing a truly outstanding end-user experience for each and every neonate.
Able to withstand long-term hypothermia treatment, COMEN water blankets are made of polyurethane materials, which are anti-corrosive, durable, and superior resistance to low temperatures, ensuring stable treatment with all the safety and comfort a baby needs.
Safe design: Material safety and durability tested using strict Biocompatibility Testing standards.
Error prevention:Water supply tube interface comes with two common channels that act as both inlet and outlet, preventing any errors during tube connection.Practical use: Large surface area accommodates the needs for neonates of all sizes.
Intimate Care
Our tried-and-tested water blanket plays a crucial role in temperature transmission during the 72-hour hypothermia treatment. With two types to choose from, they are a perfect complement to the P3/P6, providing a truly outstanding end-user experience for each and every neonate.
Able to withstand long-term hypothermia treatment, COMEN water blankets are made of polyurethane materials, which are anti-corrosive, durable, and superior resistance to low temperatures, ensuring stable treatment with all the safety and comfort a baby needs.
Safe design: Material safety and durability tested using strict Biocompatibility Testing standards.
Error prevention:Water supply tube interface comes with two common channels that act as both inlet and outlet, preventing any errors during tube connection.Practical use: Large surface area accommodates the needs for neonates of all sizes.
Quality without Breaking the Bank

Quality without Breaking the Bank


Flat-type Water Blanket
Cost-effective
Durable and Reusable
Flat design allows for easier disinfection.

Full-body wrapping
One-time-use greatly reduces cross-contamination
Easier on the skin with our non-woven fabric wrap
One-piece suit, up to 88% surface area coverage