NV50/60/70
Technology Guides Greatness
Focus on Non-Invasive Respiratory Support
-
An 18-inch touchscreen with rotating display for easier operation and observation.
-
Upgraded synchronization technology enables patients to have a comfortable breathing experience.
-
An exceptionally powerful turbine ensures effective compensation for any leakage resulting from incomplete facial non-invasive mask sealing.
Focus on Non-Invasive Respiratory Support
-
An 18-inch touchscreen with rotating display for easier operation and observation.
-
Upgraded synchronization technology enables patients to have a comfortable breathing experience.
-
An exceptionally powerful turbine ensures effective compensation for any leakage resulting from incomplete facial non-invasive mask sealing.
Pressure is Guaranteed
With optimized algorithms, the built-in turbine offers compensation to mask air leakage during non-invasive ventilation, thereby establishing the most significant power core in the industry.
Increased peak flow rate
Elevated delivery pressure
Enhanced accuracy in leakage compensation
Breathing as Casual
IV-Cycle synchronization technology adjusts trigger values based on monitored data to mimic patients' breathing patterns during non-invasive ventilation, reducing discomfort and treatment failure.
C-Free Pressure Reduction Technology
In CPAP mode, it allows NV70 to identify the optimized switching point to reduce the positive pressure of ventilation when the patient tries to exhale.
Ramp Allows Pressure to Increase Gradually
For patients with poor pressure tolerance, the pressure gradually increases to a set value over time, allowing patients to slowly adapt without discomfort.
Rising Time Facilitates Patient Adaptation
Health providers can adjust the rising time to match the patient's tolerance to the ventilator, enabling a comfortable flow rate during inhalation.
NIV for All Age Groups
NV70 provides not only non-invasive ventilation modes for adults and children but also special modes designed exclusively for newborns that are recommended by healthcare providers.
Adult/Pediatric
Neonate
Advanced NIV Modes
Proportional Pressure Support
NV70 actively responds to the patient's inspiratory effort and provides proportional support, allowing the patient to decide when to start and end gas delivery. Suitable for weaning-stage breathing exercises.Volume Guaranteed Pressure Support
Dual-adjustment mode simultaneously controls inspiratory pressure and tidal volume, reducing the risk of lung shear injury and barotrauma caused by a single limit.Nasal Intermittent Positive Pressure Ventilation
Exclusive for newborns, compatible with Infant Flow™ LP, Medijet®, NV FLOW, and NeoFlow® pressure generators.Multiple Indicators, Multiplied Outcomes
High Flow Cannula Oxygen Therapy
Wider flow range from 2 to 80 L/min.
High Flow Cannula Oxygen Therapy
Wider flow range from 2 to 80 L/min.
Oxygenation Assessment Indicators
Besides SpO2 and EtCO2, indicators such as ROX, OSI, RSS, and S/F will enhance clinical decision-making, avoid delayed intubation, improve the success rate of rescue, and directly reflect treatment outcomes.
Oxygenation Assessment Indicators
Besides SpO2 and EtCO2, indicators such as ROX, OSI, RSS, and S/F will enhance clinical decision-making, avoid delayed intubation, improve the success rate of rescue, and directly reflect treatment outcomes.
Ratio of SpO2/FiO2 to Respiratory Rate
A reliable alternative indicator of the P/F ratio (PaO2/FiO2) when there is no ABG results.
Oxygen Saturation Index
GH correlation with OI in neonates with hypoxemic respiratory failure.
Respiratory Severity Score
Medical providers can use RRS to access patients oxygenation levels without arterial blood gas (ABG) results.
SpO2/FiO2 Ratio
A reliable alternative indicator of the P/F ratio (PaO2/FiO2) when there is no ABG results.
Intelligent Interconnection
Detachable Screen for More Options
The screen can be installed on the ceiling pendant to save space on the floor between bed intervals. For the infectious department, the screen can be put outside the ward. The medical providers can control the screen outside, and the main unit works beside the patient.
Detachable Screen for More Options
The screen can be installed on the ceiling pendant to save space on the floor between bed intervals. For the infectious department, the screen can be put outside the ward. The medical providers can control the screen outside, and the main unit works beside the patient.
Your Guardian in Transportation
NV70 is equipped with a trolley, two-cylinder brackets, and built-in lithium batteries with 360 minutes capacity. NV70 meets the needs of intra-hospital transportation.
Your Guardian in Transportation
NV70 is equipped with a trolley, two-cylinder brackets, and built-in lithium batteries with 360 minutes capacity. NV70 meets the needs of intra-hospital transportation.
Tilators connect with syringe pumps, monitors, and intensive care information systems, forming a critical care solution. Such a network will energize hospital clinical service, research, and management and bring hospitals to a new level.
Tilators connect with syringe pumps, monitors, and intensive care information systems, forming a critical care solution. Such a network will energize hospital clinical service, research, and management and bring hospitals to a new level.